8 resultados para Neonates

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human rotaviruses were isolated from asymptomatic neonates at various hospitals and clinics in the city of Bangalore, India, and were found to be subgroup I specific and possess long RNA patterns (M. Sukumaran, K. Gowda, P. P. Maiya, T. P. Srinivas, M. S. Kumar, S. Aijaz, R. R. Reddy, L. Padilla, H. B. Greenberg, and C. D. Rao, Arch. Virol. 126:239-251, 1992). Three of these strains were adapted to tissue culture and found by serotype analysis and neutralization assays to be of serotype 10, a serotype commonly found in cattle but infrequently found in humans and not previously identified in neonates. By RNA-RNA hybridization, a high level of relatedness to a serotype 10 bovine rotavirus strain and a low-to-medium level of relatedness to a human rotavirus strain were observed. Since this human isolate shares a genogroup with bovine rotavirus, it is likely that it originated by interspecies transmission. A human rotavirus strain isolated from asymptomatic neonates and similar to bovine rotavirus might represent a good vaccine candidate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background & objectives: There is a need to develop an affordable and reliable tool for hearing screening of neonates in resource constrained, medically underserved areas of developing nations. This study valuates a strategy of health worker based screening of neonates using a low cost mechanical calibrated noisemaker followed up with parental monitoring of age appropriate auditory milestones for detecting severe-profound hearing impairment in infants by 6 months of age. Methods: A trained health worker under the supervision of a qualified audiologist screened 425 neonates of whom 20 had confirmed severe-profound hearing impairment. Mechanical calibrated noisemakers of 50, 60, 70 and 80 dB (A) were used to elicit the behavioural responses. The parents of screened neonates were instructed to monitor the normal language and auditory milestones till 6 months of age. This strategy was validated against the reference standard consisting of a battery of tests - namely, auditory brain stem response (ABR), otoacoustic emissions (OAE) and behavioural assessment at 2 years of age. Bayesian prevalence weighted measures of screening were calculated. Results: The sensitivity and specificity was high with least false positive referrals for. 70 and 80 dB (A) noisemakers. All the noisemakers had 100 per cent negative predictive value. 70 and 80 dB (A) noisemakers had high positive likelihood ratios of 19 and 34, respectively. The probability differences for pre- and post- test positive was 43 and 58 for 70 and 80 dB (A) noisemakers, respectively. Interpretation & conclusions: In a controlled setting, health workers with primary education can be trained to use a mechanical calibrated noisemaker made of locally available material to reliably screen for severe-profound hearing loss in neonates. The monitoring of auditory responses could be done by informed parents. Multi-centre field trials of this strategy need to be carried out to examine the feasibility of community health care workers using it in resource constrained settings of developing nations to implement an effective national neonatal hearing screening programme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epidemiology of symptomatic rotaviruses from Bangalore and Mysore in Southern India was investigated. While serotype G3 predominated throughout the 7-year study period from 1988 to 1994 in Bangalore, serotype G1 was more predominant than serotype G3 in Mysore during 1993 and 1994. Serotype G2 strains were either not detected or infrequently observed in both the cities. However, several strains with subgroup I and lsquoshortrsquo RNA pattern that exhibited high reactivity with typing MAbs specific for serotype 2 as well as other serotypes were detected throughout the period. Among the nonserotypeable strains from both cities, several exhibited dual subgroup (SGI+II) or subgroup I specificity and lsquolongrsquo RNA pattern indicating their probable animal origin. Notably, a gradual, yet highly significant reduction in rotavirus gastroenteritis, from 45.3% in 1988 to 1.8% during 1994, was observed in Bangalore in stark contrast to the consistently high (about 34%) incidence of asymptomatic infections among neonates by I321-like G10P11 type strains during the same period. Moreover, I321-like asymptomatic strains were not detected in children with diarrhea.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Consanguineous marriages are strongly favoured among the peoples of South India. Because of the potential genetic risks resulting from inbreeding, a neonatal screening project was established in 1980 in the state of Karnataka for the identification of amino acidaemias. To date, blood samples obtained by toe-stab from 98,256 neonates have been tested by thin layer chromatography, with 46 single and 70 general amino acidaemias detected. The coefficients of inbreeding (F) for the two groups of neonates were 0.0336 and 0.0350, by comparison with a previously determined F value for the general, new-born population of 0.0298. The most common single abnormality detected was tyrosinaemia, with spontaneous resolution in the majority of cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The nucleotide sequence of genes 4 and 9, encoding the outer capsid proteins VP4 and VP7 of a serotype 10 tissue culture-adapted strain, 1321, representative of asymptomatic neonatal rotaviruses isolated from neonates in Bangalore, India, were determined. Comparison of nucleotide and deduced amino acid sequences of 1321 VP4 and VP7 with previously published sequences of various serotypes revealed that both genes were highly homologous to the respective genes of serotype 10 bovine rotavirus, B223. The VP4 of 1321 represents a new human P serotype and the 1321 and related strains represent the first description of neonatal rotaviruses that appear to derive both surface proteins from an animal rotavirus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is seen at a higher frequency in many national and ethnic groups in areas of current or former malaria endemicity. A screening programme undertaken to evaluate the gene frequencies for this deficiency in the highly inbred South Indian population of Karnataka revealed that of the 5140 neonates screened, 7.8% were G6PD deficient with no correlation between the reported level of inbreeding and enzyme deficiency. An interesting finding was the equal number of male (198) and female (207) individuals, with G6PD activity of less than 3 IU. The possible implications of this finding with regard to the expression of G6PD gene is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies have shown predominant association of G10P11 type bovine rotavirus-derived reassortant strains with asymptomatic infections in newborn children in India. To understand the epidemiological and genetic basis for the origin of these strains in humans, the relative frequencies of different serotypes among bovine rotaviruses (BRVs) isolated from southern, western and central regions of the country were determined by subgroup and serotype analysis as well as nucleotide (nt) sequence analysis of the genes encoding the outer capsid proteins VP4 and VP7. Since the human G10P11 asymptomatic neonatal strain I321 possessed NSP1 from a human rotavirus, to determine its genetic origin in the bovine strains, comparative analysis of partial gene sequences from representative G10P11 strains was also carried out. The following observations were of great epidemiological significance, (i) G10P11 strains predominated in all the three regions with frequencies ranging between 55.6% and 85.2%. In contrast to the high prevalence of G6 strains in other countries, only one G6 strain was detected in this study and G8 strains represented 5.8% of the isolates, (ii) among the G10 strains, in serotyping ELISA, four patterns of reactivity were observed that appeared to correlate with the differences in electropherotypic patterns and amino acid (aa) sequence of the VP7, (iii) surprisingly, strains belonging to serotype G3 were detected more frequently (10.7%) than those of serotypes G6 and G8 combined, while strains representing the new serotype (G15) were observed in a single farm in Bangalore, and (iv) about 3.9% of the isolates were nontypeable as they exhibited high cross-reactivity to the serotyping MAbs used in the study. Comparative analysis of the VP7 gene sequence from the prototype G3 MAb-reactive bovine strain J63 revealed greatest sequence relatedness (87.6% nt and 96.0% aa) with that of serotype G3 rhesus-monkey strain RRV. It also exhibited high sequence homology with the VP7 from several animal and animal rotavirus-related human G3 strains (Simian SA11; equine ERV316 and FI-14. canine CU-1 and K9; porcine 4F; Feline Cat2 and human HCR3, YO and AU1). Partial nucleotide sequence analysis of the NSP1 gene of J63 showed greatest nt sequence homology (95.9%) to the NSP1 gene allele of the Indian G8 strain, isolated from a diarrheic child, which is likely to have been transmitted directly from cattle and 92.6% homology to that of the bovine G8 strain A5-10 suggesting the likely origin of J63 by gene reassortment between a bovine G8 strain and a G3 animal strain. Prevalence of G10P11 strains in cattle and G10P11 or P11 type reassortant strains in asymptomatic neonates as well as detection of G8P[1] strains in diarrheic children support our hypothesis for bidirectional transmission of rotaviruses between humans and cattle and origin of novel strains catalyzed by the age-old traditions and socio-economic conditions in India.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this text we present the design of a wearable health monitoring device capable of remotely monitoring health parameters of neonates for the first few weeks after birth. The device is primarily aimed at continuously tracking the skin temperature to indicate the onset of hypothermia in newborns. A medical grade thermistor is responsible for temperature measurement and is directly interfaced to a microcontroller with an integrated bluetooth low energy radio. An inertial sensor is also present in the device to facilitate breathing rate measurement which has been discussed briefly. Sensed data is transferred securely over bluetooth low energy radio to a nearby gateway, which relays the information to a central database for real time monitoring. Low power optimizations at both the circuit and software levels ensure a prolonged battery life. The device is packaged in a baby friendly, water proof housing and is easily sterilizable and reusable.